PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
September 27, 20240 citations

Open dataset on wastewater quality monitoring with adsorption and reflectance spectrophotometry in the UV-vis range

View Full Paper
PLPierre LechevallierGGGünter GruberVBVojtěch Bareš

Key Points

Key points are not available for this paper at this time.

Abstract

A major challenge in wastewater and sewer system monitoring is the development of advanced sensing technologies to improve standard pollutant measurement and allow real-time online detection of emerging contaminants. To evaluate the performance a novel hyperspectral imaging system compared to state-of-the-art ultraviolet-visible (UV-vis) sensors, this study presents a dataset from a comprehensive 25-week measurement campaign, openly available here: https://doi.org/10.25678/000D3C (Lechevallier et al., 2024a). The dataset consists of 5801 hyperspectral images of raw wastewater taken at a 30-minute resolution, as well as measurements of temperature, ammonium, flow, turbidity, pH, and UV-vis absorbance spectra taken at a 2-minute resolution. In addition, we collected 533 grab samples and analyzed them in the laboratory for conventional pollutants, including ammonium, total suspended solids, total nitrogen, dissolved organic carbon, and phosphates. Notably, we gathered 86 of these samples after four rain events and subsequently analyzed them for twenty organic chemicals, which provided valuable insights into the impact of wet weather on pollutant levels. This paper provides detailed information on the data collection and processing methodologies, along with visualizations and analysis of the processed data. Finally, we highlighted potential applications of the data, emphasizing their relevance for future research, especially data-driven modeling. In particular, we discussed four promising uses of the dataset: measuring turbidity with hyperspectral imagers, measuring ammonium with spectrophotometers, improving sensor calibration models, and developing efficient, low-cost sensors for urban drainage monitoring. Despite difficulties in the maintenance of some sensors, in particular the ion selective electrode for ammonium measurement, the dataset's high temporal resolution, the long-time span of 25 weeks, and the extensive range of analyzed pollutants, make it a valuable resource for advancing the field of urban water management.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Lechevallier et al. (2024) studied this question.

synapsesocial.com/papers/68e572d6b6db64358751384chttps://doi.org/10.31219/osf.io/y4pnm
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Guidance on effective exploitation of spectroscopic techniques for assessing wastewater discharges in water bodies2026 · 1 citations
  2. 2A novel camera-based sensor for real-time wastewater quality monitoring2024 · 9 citations
  3. 3Using Surrogate Parameters to Enhance Monitoring of Community Wastewater Management System Performance for Sustainable Operations2024 · 8 citations
  4. 4A High-Frequency and Real-Time Ground Remote Sensing System for Obtaining Water Quality Based on a Micro Hyper-Spectrometer2024 · 28 citations
  5. 5In-situ optical water quality monitoring sensors—applications, challenges, and future opportunities2024 · 66 citations