March 29, 20260 citationsOpen Access

Performance evaluation of a correlation-based spectroscopic method for ammonia equivalents in sewers and WWTP influents

View Full Paper
NNNicolas NeuenhoferSwiss Federal Institute of Aquatic Science and TechnologyPLPierre LechevallierETH ZurichJRJörg RieckermannSwiss Federal Institute of Aquatic Science and Technology

Key Points

  • This research aims to evaluate the effectiveness of UV/Vis spectrometers for measuring ammonia in wastewater.
  • Assessed in-situ UV/Vis spectrometers in two Swiss catchments
  • Compared three calibration methods: multiple linear regression, partial least squares, and random forest
  • Performed wavelength importance analysis for ammonia prediction
  • Best models achieved R² values between 0.6 and 0.8
  • Identified significant reliance on UV wavelengths for accurate ammonia predictions

Abstract

Ammonia monitoring in wastewater is essential for environmental protection and process optimization, yet traditional methods are costly and maintenance-intensive. This study evaluates the potential of in-situ UV/Vis spectrometers for monitoring ammonia equivalents in sewers and WWTP influents, which has been overlooked in literature. We assess three calibration approaches—multiple linear regression, partial least squares, and random forest—across two catchments in Switzerland. Initial results show promising predictive performance (R² of best performing models between 0.6 and 0.8). Wavelength importance analysis shows a clear reliance on UV wavelengths for ammonia predictions.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Neuenhofer et al. (2026) studied this question.

synapsesocial.com/papers/69c8c336de0f0f753b39dd0ahttps://doi.org/10.71573/xrc42133
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Determination of biochemical and chemical oxygen demand in wastewater using UV-Vis and EEM spectroscopy coupled with chemometrics2025
  2. 2Fast Tracking and Detection of Organic Matter in an Urban Sewage Treatment Plant Using Fluorescence Spectroscopy and UV-Vis Absorption Spectroscopy2024 · 1 citations
  3. 3Open dataset on wastewater quality monitoring with adsorption and reflectance spectrophotometry in the UV-vis range2024 · 1 citations
  4. 4Using Surrogate Parameters to Enhance Monitoring of Community Wastewater Management System Performance for Sustainable Operations2024 · 8 citations
  5. 5Feasibility of using in situ UV/Vis spectrometer probe for measuring COD in WWTP based on UASB reactor2024