A fiber-optic hydrogen gas sensor using a platinum-supported tungsten oxide-silica composite film was fabricated. This sensor utilizes the absorption of the evanescent field interaction in the hydrogen sensitive clad which was composed of WO 3 and SiO 2 , coated on a silica core with sol-gel process. As a first step, transmission spectra of sensing film itself were measured. The transmittance of the sensitive film decreased in the range of wavelengths above about 500 nm after exposure to pure hydrogen, and the change in transmittance at 1300 nm was greater than that at 850 nm. Then, fiber optic sensor device was fabricated, and the amount of propagating light was measured. In the case of using the light source with a wavelength of 1300 nm, the sensitivity with respect to the hydrogen response was nearly twice and the response speed was faster, compared with those at 850 nm.