Aim We aim to compare the burden of Level 1 (<4 mmol/L) and Level 2 (<3 mmol/L) hypoglycaemia between type 2 diabetes (T2D) patients with and without chronic kidney disease (CKD). Methods T2D subjects with and without CKD (eGFR<60 mL/min/1.73 m 2 ) were recruited from a tertiary‐care hospital. Subjects wore the Freestyle Libre‐Pro sensor for 2 weeks. The number of hypoglycaemic events and intra‐day difference in Level 1 and 2 hypoglycaemias were compared between the cohorts. Results We recruited 134 subjects: 74 with CKD (44 M:30F) and 60 without CKD (36 M:24F), with no difference in HbA1c between the two cohorts (66 ± 20 vs 64 ± 16 mmol/mol, p = 0.529). The CKD cohort had increased level 1 (OR 1.73, p = 0.011), level 2 hypoglycaemias (OR 2.16, p = 0.002), and glycaemic variability than the non‐CKD cohort (35.3 ± 9.5 vs 32.3 ± 6.8%). The CKD cohort had more level 2 hypoglycaemia events nocturnally compared to day at 1.9 ± 3.1 vs. 1.4 ± 2.5 events/person within the two week sensor wearing period ( p = 0.022), whereas there was no significant intra‐day difference in the number of such events within the non‐CKD cohort. Conclusions The CKD cohort has a greater burden of hypoglycaemia despite being treated to similar HbA1c targets. The greater number of nocturnal events warrants safety concern. Interstitial fluid glucose targets should be incorporated into the glycaemic guidelines for T2D patients with CKD.
No takes yet. Share an insight, caveat, or question.
Tian et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: