Answers are grounded in this paper and cite their sources.
The proposed work uses the CFD commercial flow solver Ansys CFX. This solver is a finite volume-based method. Ansys CFX is used to compute heat transfer at the fluid-solid interface using its CHT module to improve the efficiency of the cooling PV system. The cooling PV system proposed by Wilson is the best-chosen design since it uses a confined water flow and then no water is lost or evaporated also it uses the hydraulic head of water from a tank without the use of a circulating pump. According to the last studies of a confined flow, the k-w turbulent model of Wilcox is selected to study heat transfer inside a 3D geometry proposed by Wilson. The recirculation area effect on heat transfer lowers the wall heat flux at the solid-fluid interface so this recirculation area must be avoided. To achieve the recirculation area, different cooling PV systems geometries can be investigated in future studies.
No takes yet. Share an insight, caveat, or question.
Ridha Hannat (2024) studied this question.