Answers are grounded in this paper and cite their sources.
Abstract This article documents the design, calculation and commissioning process of an office building with one-way reinforced concrete floor slabs with perforated ribs, obtained using the 68 cm H-ONE system. This is the first project to use this type of formwork, designed by Holedeck and BIS structures. In the work carried out, this solution resulted in a saving of 0.214 m³/m² (50%) of concrete and 10.4 kg/m² (29%) of passive steel in the slab compared to a solution based on reinforced concrete slabs. This material saving resulted in a reduction in CO₂ emissions of 85 kgCO₂/m² (45%) according to the life cycle analysis of the building. When considering the entire structure, this reduction was 57% higher, as lightening the floor slab also reduces the size of the columns and foundations.
No takes yet. Share an insight, caveat, or question.
Carrera et al. (2024) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: