Flow in test of highly loaded compressor cascade often deviates from the two-dimensional flow due to end-wall separation. As a traditional method, boundary layer suction often has problems, such as complicated device and unclear required suction flow rate. In this work, a novel method for cascade tests, blade end slot, was proposed to make test results better reflect the performance of two-dimensional profile in a highly loaded compressor cascade. The effect of slot jet flow on end-wall separation was investigated. The results show that slots can effectively suppress corner separation and make the flow at mid-span tend to two-dimensional flow. The slot jet flow near the core of corner separation can speed up the low-energy fluid in the corner region and suppress the separation. When the slot is of 10% span height and at about 80% chordwise position, the performance deviation between mid-span of cascade and the two-dimensional profile is less than 5% at large positive incidence positions.