Answers are grounded in this paper and cite their sources.
The application of shear horizontal (SH) guided wave transducers in high-temperature structural health monitoring (SHM) is a topic of significant interest across various industrial engineering sectors. In this study, we utilized the novelty piezoelectric crystal of near stoichiometric lithium niobate (NSLN), which exhibited a robust piezoelectric response (d15 = 77.6 pC/N@room temperature). Next, the pure thickness shear vibration mode d15′ through size optimization was designed. It was demonstrated that the NSLN-based ultrasonic guided wave transducers utilizing the optimum d15′ mode were proficient in transmitting and receiving pure fundamental SH wave (SH0 wave) along two orthogonal main directions (0° and 90°) over a wide frequency range (100–350 kHz), exhibiting strong response to the SH0 wave. Under the driving voltage of 100 V, the signal voltages of the NSLN-based transducer were found to be on the order of 200.3 and 11.8 mV at room temperature and high temperature of 650 °C, respectively. Moreover, the NSLN-based SH0 transducer showcased its better defect localization ability, and the signal-to-noise ratio (SNR) sensitivity of NSLN-based transducer was evaluated to be 16.1 dB at high temperature of 650 °C. To sum up, the ultrasonic wave transducer based on NSLN crystal demonstrated higher potential applications for in situ SHM under elevated temperatures.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: