This is the authors' abstract. We don't add key points for this paper.
In 2021, the City of Fayetteville (the City) performed a remote inspection of the 48-in. gravity sewer from Gregg Avenue to Sunshine Road. Installed in 2006 via hand tunneling, the pipeline is a 48-in. diameter centrifugally cast fiber-reinforced polymer mortar (CCFRPM) pipe inside a 72-in. diameter steel tunnel liner, originally designed with a grouted annulus. The tunneled segment is 913-ft long with fill cover up to 24 ft and runs under Interstate 49 and the Southbound Highway 112 Exit Ramp. The City's inspection revealed a 100-ft section of localized cracking, damage, and high deflections under the interstate exit ramp, which required trenchless repair. The City retained the investigate-design-build team of Structural Technologies and their subconsultant, Simpson Gumpertz & Heger Inc., to investigate and repair the tunnel. This case study highlights the numerous challenges and multidisciplinary efforts of the project team to successfully implement trenchless repair, including setting up a bypass for the root cause investigation, discovery of unstable tunnel conditions, design of custom shoring solutions, and a three-stage tunnel stabilization effort to allow for installation of a CFRP liner. Thermal sensitivity of the carrier pipe also required a thermal control plan to limit the heat of hydration during grouting.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Richie et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: