Solid-liquid (S-L) interfaces are found in numerous engineering applications, such as lubrication and coating systems as well as thermal interface materials. Understanding the interactions between (S-L) is crucial for optimizing various engineering applications. The main objective of this study is to provide insight regarding liquid adsorption on solid surfaces using non-equilibrium molecular dynamics simulations. To achieve this goal, a liquid confined between solid surfaces will be modeled to match the real state of contact interfaces using a constant temperature as a baseline. The results highlight a significant relationship between the peak height values of the liquid adsorption layer, density profile, and radius of gyration. Specifically, the peak height density at the S-L interfaces for the crystal plane (110) is 784.756 kg/m3, followed by (100) at 801.786 kg/m3, and finally the highest is for the crystal plane (111), at 966.940 kg/m3. Whereas the radius of gyration at the S-L interfaces for crystal planes (100) and (111) is approximately 7.45 × 10-21 m2, but for crystal plane (110) it is less and measures approximately 7.06 × 10-21 m2. Conclusion, the adsorption layer of solid density near solid-liquid interfaces is significantly influenced by the peak height of the solid's density. Higher density results in a higher adsorption layer of liquid near solid-liquid interfaces. The number of solid density layers does not affect the height of adsorption layers for liquids.
No takes yet. Share an insight, caveat, or question.
Rama et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: