Observational analysis reveals asymptomatic bacterial colonisation in hardware removal patients, highlighting widespread subclinical device contamination.
Background Bacterial infection after hardware implantation in orthopedic and trauma surgery is devastating, resulting in increased hospital costs and stays, multiple revision surgeries, and prolonged use of antibiotics. The present study aims to determine whether a symbiotic relationship between the human organism and bacteria in hardware implantation may be present, without clinically evident infection. Materials and methods We studied explanted devices for microbiological analysis, using the sonication technique, from patients who underwent surgical removal of musculoskeletal hardware for mechanical reasons. None of the patients included in the study had clinical or biochemical signs of infection. Results Forty-nine patients were enrolled. Cultures tested positive for bacteria in 42.8% of the 49 patients (21 of 49). In 13 patients, Gram-positive bacteria were isolated, while Gram-negative bacteria were isolated from nine patients. The most frequent bacterial species found was
No takes yet. Share an insight, caveat, or question.
Previ et al. (2024) studied this question.