Currently, widely used glucose sensors rely on enzyme catalysts, which suffer from issues such as enzyme inactivation, high production costs, and insufficient stability. To address these challenges, this study fabricated TiO₂ films on Ti sheets using radio frequency magnetron sputtering and subsequently modified Au nanoparticles (NPs) and CuO films via direct current magnetron sputtering. Then, Au and CuO co-modified TiO₂ (CuO-Au@TiO₂) photoelectrode with a Z-type band structure was prepared, enabling enzyme-free glucose detection via photoelectrochemical (PEC) sensing technology. The optimized photoelectrode exhibited high sensitivity for glucose detection, with values of 7300 μA μM⁻¹ cm-²(0–1 mM) and 500 μA μM⁻¹ cm⁻² (1–10 mM) under AM 1.5G illumination at a bias of 0.2 V (vs. Ag/AgCl). The detection limit was determined to be 58.14 μM (Signal/Noise = 3), with excellent stability, repeatability, and selectivity. Spectral and PEC performance analyses revealed that the outstanding sensing performance of the CuO-Au@TiO₂ photoelectrode can be attributed to: (1) unique Z-Type band structure promoting carrier separation; (2) the local surface plasmon resonance (LSPR) effect induced by Au NPs enhancing light absorption; (3) CuO can undergo a specific enzyme-like catalytic reaction with glucose molecules under alkaline conditions. This research offers a novel, convenient, and accurate monitoring approach for diabetes management and prevention.