Answers are grounded in this paper and cite their sources.
Gas evolution in Li and Na ion batteries is a key problem as it is a sign of electrode degradation and electrolyte reduction. Gas evolution is caused by breakdown of electrolyte solvents and can release flammable gases leading to thermal runaway. As new and more stable electrodes, electrolyte, or electrolyte additives are implemented, it is crucial to monitor their performance and ensure thermal safety. Covalent Metrology is an analytical service lab based in Sunnyvale CA that serves as an extension of your battery R&D team. First, I will describe Covalent Metrology’s expertise, capabilities, and flexible workflows. I will then highlight some well-established analytical methods, such as GCMS and NMR to characterize volatile and non-volatile breakdown products of the electrolyte. Lastly, I will discuss the use of Scanning Acoustic Microscopy (SAM) and Glow Discharge Optical Emission Spectroscopy (GD-OES) to investigate the spatial distribution of electrolyte in a battery. We believe this hybrid metrology approach can provide important feedback toward developing better batteries more safely.
No takes yet. Share an insight, caveat, or question.
Austin M. Barnes (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: