In this study, state‐of‐the‐art on‐line pyrolysis MS (OP‐MS) equipped with temperature‐controlled cold trap and on‐line pyrolysis GC/MS (OP‐GC/MS) injected through high‐vacuum negative‐pressure gas sampling (HVNPGS) programming are originally designed/constructed to identify/quantify the dynamic change of common permanent gases and micromolecule organics from the anode/cathode–electrolyte reactions during thermal runaway (TR) process, and corresponding TR mechanisms are further perfected/complemented. On LiC x anode side, solid electrolyte interphase (SEI) would undergo continuous decomposition and regeneration, and the R‐H + (e.g., HF, ROH, etc.) species derived from electrolyte decomposition would continue to react with Li/LiC x to generate H 2 . Up to above 200 °C, the O 2 would release from the charged NCM cathode and organic radicals would be consumed/oxidized by evolved O 2 to form CO x , H 2 O, and more corrosive HF. On the contrary, charged LFP cathode does not present obvious O 2 evolution during heating process and the unreacted flammable/toxic organic species would exit in the form of high temperature/high‐pressure (HT/HP) vapors within batteries, indicating higher potential safety risks. Additionally, the in depth understanding of the TR mechanism outlined above provides a clear direction for the design/modification of thermostable electrodes and non‐flammable electrolytes for safer batteries.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2024) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: