PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
August 8, 2024Buildings2 citationsOpen Access

Optimizing Seismic Performance of Tuned Mass Dampers at Various Levels in Reinforced Concrete Buildings

View Full Paper
HNHosein NaderpourASAsghar SoltaniMatinAKAli Kheyroddin

Key Points

Key points are not available for this paper at this time.

Abstract

This study aimed to rigorously evaluate the impact of tuned mass dampers (TMDs) on structural response under seismic excitation. By strategically placing TMDs at various levels within the structures, the research sought to determine their effectiveness in mitigating structural movement. A single-degree-of-freedom (SDOF) system incorporating TMDs was utilized to model structures of 10, 13, and 16 stories, each configured with TMDs at different heights. The structures were subjected to near-fault earthquakes to assess the efficacy of TMDs in reducing structural response. The findings revealed significant enhancements in structural performance when TMDs were optimally positioned. Specifically, a 50% reduction in both acceleration and displacement, alongside a 65% decrease in maximum drift, underscored the effectiveness of TMD deployment. Furthermore, the study demonstrated that distributing multiple TMDs along the height of the structure provided superior drift control. Notably, positioning TMDs within the upper one-third of the structure yielded the most pronounced improvements in acceleration, displacement, and maximum drift. Finally, the research indicates that the strategic incorporation of TMDs can significantly enhance the seismic resilience of structures. The results highlight the substantial benefits of TMDs in optimizing acceleration, displacement, and drift, thereby affirming their critical role in seismic design and retrofitting strategies.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Naderpour et al. (2024) studied this question.

synapsesocial.com/papers/68e5cfffb6db6435875665e7https://doi.org/10.3390/buildings14082443
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Advanced seismic retrofitting with high-mass-ratio Tuned Mass Dampers2024 · 29 citations
  2. 2Enhancing Building Stability and Seismic Resilience with Water-Added Tuned Mass Dampers2024 · 1 citations
  3. 3Resilience-Based Seismic Optimization of Buildings Using Tuned Mass Dampers2026
  4. 4Effectiveness of single and multiple tuned mass damper in seismic response reduction of RCC Framed Building2024
  5. 5Seismic control of tall buildings using vertically distributed multiple tuned mass dampers2024 · 3 citations