Purpose To evaluate the relationship between delivered radiation (RT) and post-RT inversion-recovery ultrashort-echo-time (IR-UTE) MRI signal-intensity (SI) in gynecologic cancer patients treated with high-dose-rate (HDR) brachytherapy (BT). Methods Seven patients underwent whole-pelvis RT (WPRT) followed by BT to the high-risk clinical target volume (HR-CTV). MR images were acquired at three time-points; pre-RT, post-WPRT/pre-BT, and 3–6 months post-BT. Diffuse-fibrosis (F Diffuse ) was imaged with a non-contrast dual-echo IR (inversion time [TI] = 60 ms) UTE research application, with image-subtraction of the later echo, only retaining the ultrashort-echo SI. Dense-fibrosis (F Dense ) imaging utilized single-echo Late-Gadolinium-Enhanced IR-UTE, acquired ∼ 15 min post-Gadavist injection. Resulting F Diffuse and F Dense SI were normalized to the corresponding gluteal-muscle SI. Images were deformably registered between time-points based on normal tissue anatomy. The remnant tumor at both time-points was segmented using multi-parametric MRI. Contours corresponding to the 50%, 100%, 150%, and 200% isodose lines (IDLs) of the prescription BT-dose were created. Mean F Diffuse and F Dense SI within (i) each IDL contour and (ii) the remnant tumor were calculated. Post-BT F Diffuse and F Dense SI were correlated with prescribed BT-dose. To determine the relationship between BT-dose and IR-UTE SI, the differences in the post-BT F Dense across IDLs was determined using paired t-tests with Bonferroni correction. Results F Dense was higher in regions of higher dose for 6/7 patients, with mean ± SD values of 357 ± 103% and 331 ± 97% ( p = .03) in the 100% and 50% IDL, respectively. F Dense was higher in regions of higher dose in the responsive regions with mean ± SD values of 380 ± 122% and 356 ± 135% ( p = .03) in the 150% and 50% IDL, respectively. Within the segmented remnant tumor, an increase in prescribed dose correlated with an increase in F Dense post-BT ( n = 5, r = .89, p = .04). Post-BT F Diffuse inversely correlated ( n = 7, r = -.83, p = .02) with prescribed BT-dose within the 100% IDL. Conclusions Results suggest that F Dense SI 3–6 months post-BT is a sensitive measure of tissue response to heterogeneous BT radiation-dose. Future studies will validate whether F Diffuse and F Dense are accurate biomarkers of fibrotic radiation response.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Sheikh et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: