We report the first reverse-phase, high performance liquid chromatography (RP-HPLC) method for the rapid and simple simultaneous detection and quantification of minocycline and ascorbic acid in raw and pharmaceutical dosage forms. Detection was performed on a Sunniest C-18 column (5 μm particle size, 150 mm × 4.6 m mi.d(, at UV wavelength of 255 nm. The mobile phase consisted of potassium dihydrogen phosphate pH 2.8: Acetonitrile: Methanol (85:10:5), with 0.6 v/v% TEA and adjusted with orthophosphoric acid to a pH of 2.8 in an isocratic elution mode, with a flow rate of 0.8 mL/min. Performed analysis on the method proved that the newly developed method was sensitive, selective, accurate, precise, and robust. The method demonstrated good linearity with r2 = 0.9999 (n = 7) for both drugs and was validated in the sample concentration ranges of 1–100 and 5–500 µg mL−1 for minocycline and ascorbic acid, respectively. Both intra- and inter-day precisions were less than 2 % for both drugs, with limits of detection of 1.59 and 7.89 µg/mL and limits of quantification of 4.83 and 23.89 µg/mL, for minocycline and ascorbic acid, respectively. The applicability of the method was demonstrated by accurately determining the drug content of two commercial pharmaceutical formulations.
No takes yet. Share an insight, caveat, or question.
Al-Karaki et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: