An intelligent control system for Non-Evaporable Getter (NEG) pumps was designed and developed. The main functions of the system include remote monitoring and remote control of key parameters of the NEG power supply, intelligent control of NEG working status according to NEG saturation status and vacuum chamber status, especially intelligent warning and protection of NEG from vacuum leaks and NEG supersaturation. The intelligent control system is proven stable and reliable, which provides a feasible logic architecture and control design for NEG pump application in future fusion devices.