Answers are grounded in this paper and cite their sources.
Accurate prediction of smart meter faults is of great significance to ensuring reliable operation of power distribution systems. At present, most methods only alleviate the decision boundary shift problem in fault prediction from the perspective of sample number balance and do not fully consider the sample distribution in the overlapping area after balancing. This paper proposes a smart meter fault classification method based on generated sample distribution optimization, which transforms the sample rebalancing problem into a generated sample distribution optimization problem. These methods establish a multi-objective optimization model for distributing newly generated samples. During the optimization process, an adaptive differential mutation strategy is used to increase the diversity of generated samples. Data complexity is introduced to improve the crowding degree in the original NSGA-II, and the sample set with lower data complexity is retained to avoid generating samples that increase overlap. Experimental results on 12 KEEL and UCI imbalance classification public datasets and smart meter actual fault datasets show that the proposed algorithm has significant advantages in handling smart meter fault classification problems compared with eight typical methods.
No takes yet. Share an insight, caveat, or question.
Qin et al. (2024) studied this question.