This is the authors' abstract. We don't add key points for this paper.
This article presents a pipeline analog-to-digital converter (ADC) background calibration method that combines genetic algorithm (GA) and neural network (NN) algorithm. The proposed method uses ADC outputs or individual stage sub-ADC outputs for NN training , employs GA for global optimization of the NN's initial setup to avoid local optima traps, and utilizes a parallel pipeline architecture to create a high-throughput calibration circuit with optimized multiply-accumulator (MAC) to minimize resource consumption. Through simulation on a 6-stage 14-bit pipelined ADC model, the proposed method demonstrated superiority over traditional calibration techniques and other NN-based calibration strategies. Specifically, after calibration, the signal-to-noise ratio (SNDR), spurious-free dynamic range (SFDR), and effective number of bits (ENOB) are significantly improved from 57.72 dB, 59.77 dB, and 8.79 bits to 104.61 dB, 152.64 dB, and 17.08 bits, respectively.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Li et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: