The cascaded H-bridge (CHB) based solid-state transformer is an attractive solution to integrate large-scale photovoltaic (PV) power plants into medium-voltage grids with high power quality in a controllable and scalable manner. The dc-link voltage balance of the CHB is critical to the lifespan of capacitors and semiconductor devices, grid-current quality, and the system's stable operation. However, with the conventional level-shifted pulsewidth modulation, the output power and dc-link voltage of each module are intrinsically imbalanced, which make the switching pulse permutation necessary. Although voltage balancing can be reclaimed using the pulse rotation scheme, the low permutation frequency in the existing methods increases the ripples in the dc-link voltages, which affects the maximum power point tracking efficiency. To tackle this challenge, a novel high-frequency pulse permutation scheme is proposed for the CHB-based PV solid-state transformer, and the implementation procedure based on an improved sorting method is provided. The proposed scheme can effectively ensure the dc-link voltage balance over a wide regulation range without the penalty of additional switching actions. The effectiveness of the proposed high-frequency pulse permutation scheme is validated with the experiments on a 3-kW prototype.
No takes yet. Share an insight, caveat, or question.
He et al. (2024) studied this question.