A 12-year-old male came to our Emergency Department with chief complaints of pain and inability to move the right shoulder for one day following a fall while playing. The range of motion of the right shoulder was restricted and painful in all directions. Initial radiographs revealed a transverse, displaced proximal humerus fracture at the head-shaft junction. The patient was managed by closed reduction internal fixation with percutaneous K-wiring (Kirschner wires). The K-wires were removed after four weeks, and the shoulder was mobilized. The patient had a near-normal and pain-free range of motion at three months of follow-up. Percutaneous K-wiring remains a viable option for the treatment of paediatric proximal humerus fractures, and good post-operative rehabilitation can help restore near-normal function, as demonstrated in this report.
No takes yet. Share an insight, caveat, or question.
Nair et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: