Answers are grounded in this paper and cite their sources.
The Gas-Liquid Cylindrical Cyclone (GLCC©) is an outstanding compact separator known for its efficient separation of gas-liquid mixtures and compact design. To ensure high separation efficiency, it is important to mitigate one of two unwanted phenomena known as Gas-Carry-Under (GCU) at the outlet of the GLCC which in part is achieved by implementing adequate control configurations downstream of the GLCC. These control configurations regulate the liquid level ensuring efficient separation in the GLCC and have been deployed in the industry for different field applications. In this project, the active control configuration is applied to explore the limits of the electrically actuated Atlas Severe Service control valves installed in the gas and liquid legs of the GLCC at various flow conditions, aimed to improve the GLCC separation efficiency. The main objective of this study was to acquire data on two-phase (namely air-mineral oil, air-water) and three-phase flow (air-mineral-oil-water) exploring the effects of control valve response time and fluid composition on GCU. Furthermore, the acquired data were compared with similar empirical data from pneumatically actuated control valves in conjunction with the GLCC. All this was accomplished by modifying the existing GLCC test section of the 4-phase TUSTP experimental flow loop at the University of Tulsa equipped with a state-of-the-art data acquisition system. Analysis of the experimental data shows that the GCU is greater for air-mineral oil flow conditions as compared with air-water. In addition, the data shows that GCU decreases with an increase in the superficial liquid velocity for both two-phase and three-phase flow conditions. The data acquired using the Atlas Severe Service control valves showed higher GCU for both two and three-phase flow across various flow conditions when compared with similar data for the existing pneumatically actuated control valves. This in part is owing to the lag time in response between the Atlas Severe Service valve synchronous motor actuator and the Helical bevel gear-drive control valves. The implementation of a fast-acting servomotor actuator to the Atlas Severe Service control valve configuration could mitigate GCU and improve the overall separation efficiency of the GLCC.
No takes yet. Share an insight, caveat, or question.
Awofuwa et al. (2024) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: