The microbial contamination of eye drop tips and caps varies between 7.7% and 100%. In seeking patient protection and continuous improvement, the Pharmacy Department in the Sterile Ophthalmological and Oncological Preparations Unit at Cochin Hospital AP-HP, Paris, France, conducted a two-phase study to compare the antimicrobial efficiency and practical use of standard packaging and a marketed eye drop container incorporating a self-decontaminating antimicrobial green technology by Pylote SAS at the tip and cap sites. The first phase was conducted in situ to identify the microbial contaminants of eye drops used in the hospital and community settings. A total of 110 eye drops were included for testing.
No takes yet. Share an insight, caveat, or question.
Roquefeuil et al. (2024) studied this question.