In this study, Inconel625+30%Al 2 O 3 (IN30AL) blended powders were sprayed on a commercially used boiler steel ASTM SA210 GrA1 using high-velocity oxy-fuel approach (HVOF). The microstructure, mechanical properties and elevated temperature erosion behavior of post-processed coatings and as-sprayed IN30ALcoatings were investigated. The elevated temperature erosion studies on IN30AL coatings both as-sprayed and post-processed were investigated at 900 °C temperature at two impact angles 30° and 90° using standard high temperature erosion test rig. Phase composition, interface of substrate/coating, and morphologies of eroded coatings were examined using x-ray diffraction, x-ray maps, scanning electron microscope, & energy dispersive spectrometer techniques. Compared with the as-sprayed IN30AL coatings, the heat-treated coatings have refined microstructure, better mechanical properties which improve the elevated temperature erosion resistance of IN30ALcoatings.
No takes yet. Share an insight, caveat, or question.
Prashar et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: