This research occurred because problems arose, one of which was a leak in the tank from welding in the tank fabrication with the connecting material being Stainless Steel 316L. The welding process is very important to influence the results and function of the output product from this fabrication. There were leaks in 4 of the 8 tanks, namely at the welded joints. Variations in current strength in the welding machine are one of the factors that influence the welding results. In this study, we analyzed the welded joints with variations in current strength, including 60 A, 70 A, and 80 A. The analysis tests were tensile testing, hardness testing, and X-RD to find out what the deviation is for variations in current strength and to know the results of crystal structure and uniform current strength settings for maximum results and overcoming leakage problems.