In this study, the seismic response of a newly constructed RC building, which suffered collapse-level damage during the February 6, 2023 Kahramanmaras earthquake, is simulated through nonlinear response history analyses, using model configurations representing the as-built state of the building, as well as hypothetical code-compliant and CFRP-strengthened states. Analysis results show that in its as-built state, the collapse of the structure was not unexpected, whereas code-compliant confinement detailing would have probably resulted in collapse-prevention-level performance, and CFRP-strengthening of the building would have significantly improved its seismic performance and would likely have prevented total collapse.
No takes yet. Share an insight, caveat, or question.
Tura et al. (2024) studied this question.