INTRODUCTION Modifications to Bentall procedure with usage of bioprosthetic valve instead of mechanical valve allowed freedom from anticoagulation and possibly led to lower morbidity.[1] However, it comes with the downside of structural valve degeneration. Transcatheter aortic valve implantation (TAVI) has been used in aortic regurgitation and valve-in-valve (VIV) procedures. The use of TAVI to treat valve degeneration specifically in post-bioprosthetic Bentall patients has been described in a few case reports since 1968.[2,3,4] We detail a successful transcatheter aortic VIV implantation in a patient who underwent a bioprosthetic Bentall procedure, review literature on the technical aspects of the procedure, and propose an approach for preprocedure planning, execution and postprocedural care. CASE REPORT A 38-year-old woman presented with shortness of breath. She had a significant history of thoracic aortic aneurysm treated with Bentall operation with bioprosthetic aortic valve replacement, using bioprosthetic aortic valve, Gore-Tex tube graft and coronary reimplantation 11 years ago. The patient did not have features of Marfan's syndrome. She was on follow-up, with serial transthoracic echocardiogram demonstrating well-functioning aortic prosthesis without aortic regurgitation. Clinical examination revealed loud pulmonary component of second heart sound with grade 4 early diastolic murmur over the lower left sternal edge and associated thrill. Transthoracic echocardiogram demonstrated severe aortic valve prosthesis regurgitation from malcoaptation of bioprosthetic valve anterior leaflet. Aetiology of acute aortic regurgitation was deemed to be graft failure. There was an increase in left ventricular filling pressures and pulmonary hypertension (pulmonary artery systolic pressure of 66 mmHg). She was offered the surgical option of redo Bentall with mechanical valve or percutaneous transcatheter aortic VIV implantation. Society of Thoracic Surgeons score for adult cardiac surgery risk was low (2.81%). The patient was counselled accordingly, but elected for TAVI due to concerns over warfarin in pregnancy, as she was planning to start a family. Preprocedural analysis The area of true internal diameter and stent internal diameter of the sewing ring of graft conduit were measured at 196.2 mm2 and 420.3 mm2, respectively [Figure 1].[5] With significant discrepancy between these two areas, valve expansion was predicted to take place between the true internal diameter and the stent internal diameter, with significant anchorage conferred by tissue internal to the sewing ring. As there was no calcification and dominantly aortic regurgitation, a 23-mm Edwards Sapien 3 balloon expandable prosthesis was used for oversizing of over 200% when compared against the true internal diameter. Risk of root complications would be mitigated by the presence of a firm sewing ring.Figure 1: (a) 3D imaging of the bioprosthesis Bentall graft. Computed tomography images of the aortic valve measurements of the (b) inner dimensions and (c) outer dimensions of the annulus.Procedural details The patient underwent TAVI VIV via transfemoral approach with transthoracic guidance. The sewing ring was visualised with cineangiography [Figure 2]. Aortic root angiography with rapid ventricular pacing was performed to confirm the sewing ring's position relative to the valve leaflet and coronary artery take-off. The native valve was crossed via right flail coronary cusp using a pigtail catheter, and an extra small curve Safari wire was positioned at the left ventricular apex. This was followed by tracking an Edward Sapien Commander delivery system over the Safari wire. There was marked movement of valve marker in relation to sewing ring during systole and diastole, but this was stabilised with rapid pacing, allowing safe and slow deployment of a size 23-mm Edwards Sapien 3 balloon expandable prosthesis under fluoroscopic guidance. The valve deployment was intentionally performed more slowly than in conventional TAVI to create more stability, options of slight repositioning and finally anchoring of valve to graft towards the end of inflation. Good valve positioning was confirmed with contrast fluoroscopy [Figure 2]. Haemodynamic tracings showed satisfactory separation of aortic and left ventricular end-diastolic pressure curves with improvement of aortic regurgitation index from 6 to 44. Transthoracic echocardiogram did not detect any paravalvular or transvalvular leak, and no significant forward gradient was observed. The patient was well postprocedure and discharged 48 h later. Repeat echocardiogram demonstrated a well-functioning aortic prosthesis with no regurgitation [Figure 2].Figure 2: Cineangiographic images of the bioprosthetic Bentall graft. (a) With visualisation of the sewing ring (arrows). (b) Positioning of the TAVI valve in relation to the sewing ring (dotted line). (c) The excess movement was mitigated by rapid transvenous pacing, with slow deployment of the size 23-mm Edwards S3 balloon expandable prosthesis during fluoroscopy. (d) Satisfactory angiographic results post-TAVI with no regurgitation on fluoroscopy. Transthoracic echocardiogram (e) pre-TAVI zoomed in parasternal long-axis view and (f) pre-TAVI parasternal long-axis view with colour TAVI. Transthoracic echocardiogram (g) post-TAVI zoomed in parasternal long-axis view and (h) post-TAVI parasternal long-axis view with colour. TAVI: transcatheter aortic valve implantationSCOPING REVIEW: METHODS AND RESULTS A PubMed search was conducted on 28 February 2021 for articles related to patients who underwent TAVI for failed bioprosthetic Bentall. The search terms included '(Transcatheter aortic valve replacement or TAVR or transcatheter aortic valve implantation or TAVI) and (Bentall or bioprosthetic)', with no date filter applied. In addition, manual sieving of references from retrieved articles was done. Only papers that identified patients who underwent TAVI after failure of previous Bentall bioprosthesis implant were included. Papers that described surgical repair of failed Bentall bioprosthesis or did not indicate prior Bentall bioprosthetic use were excluded.[6] The identified references were imported into Endnote X9 and duplicates were removed. Of 598 papers retrieved, a total of six included articles with nine cases of VIV TAVI after bioprosthetic Bentall procedure have been reported [Table 1].[2,4,7,8,9,10] Including our patient, there were five females and five males, with age ranging from 33 to 84 years (median 65 years). After bioprosthetic Bentall procedure, two patients had bioprosthetic valve stenosis, six had regurgitation and one had mixed pathology. The most common approach was transfemoral (n = 5, including our patient), followed by transcarotid (n = 3) and transapical (n = 1). All cases considered a transfemoral first approach, with alternative approaches if there were access site concerns. Four patients had Edwards Sapien balloon expandable valve, including our patient, five had Medtronic CoreValve and one had Acurate neo M. The valve size used ranged from size 23 mm to 26 mm. Majority of the cases were successful, except for one case of VIV prosthesis embolisation due to difficult positioning of 26-mm Medtronic CoreValve.[4] The literature review is summarised in Table 1.Table 1: Summary of included studies.aDISCUSSION The combination of bioprosthetic Bentall procedure and TAVI has only been reported in six case studies.[2,4,7,8,9,10] Challenges identified in previous case reports included increased coronary obstruction risk from low coronary ostia height, short virtual transcatheter heart valve to coronary distance and Bentall straight tube graft,[2] chronic ascending aorta or left subclavian artery dissection flap, aortic aneurysm at the level of graft and native aorta anastomosis restricting transfemoral access,[7,8] and porcelain aorta with severe calcification in homograft valve.[4] Our case highlights the challenges faced by operators using a TAVI approach to replace a failing graft in previous bioprosthetic Bentall procedure as compared to usual VIV, as a result of valve sizing and positioning. Valve sizing was difficult, as in the case of regurgitation without significant stenosis or calcification where more oversizing was required. Valve positioning was challenging due to (a) presence of flail leaflet, where valve leaflet position might be completely different compared to the initial position, and (b) difficult visualisation of ideal virtual annulus on preprocedural fluoroscopy image. Patient selection and counselling are important for a successful procedure. Patient preferences and underlying surgical risk scores should be accounted for. Counselling includes possibilities of valve embolisation, coronary obstruction, need for multiple valve placement due to regurgitation and need for reoperation from bioprosthetic valve structural deterioration. The predicted 15-year risk of needing reoperation as a result of structural deterioration for bioprosthetic valve is 30% for patients 40 years of age.[11] Rigorous analysis of echocardiographic and computed tomography imaging should be performed preprocedure. Computed tomography imaging is essential in (a) revealing where the valve should be 'crossed' with high reproducibility, simulating fluoroscopic views; (b) assessment of coronary implantation sites, allowing operators to choose a suitable implantation depth to avoid coronary obstruction; (c) assessment of aortic graft dimensions at the ascending aorta level, which may provide additional anchor points; and (d) detection of aneurysms or aortic arch and descending aorta dissection, which affects the access route choice. The sewing ring of the graft conduit is the most rigid structure and should be regarded as the virtual annulus, with measurements taken at this level. Sizing of valve should favour the 'outer dimension' measured for best approximation against the sewing ring and avoid valve embolisation. Presence of pannus or calcification at the sewing ring or leaflets would allow better valve anchorage; if not, greater oversizing is required. Choice and sizing of TAVI valve should be dependent on analysis of coronary interaction, sewing ring size, and leaflet and sewing ring anchorage. Advantages of balloon-expandable valves include better precision in valve sizing by allowing slight over- or underinflation and future reaccessing of coronary arteries if required, whereas self-expanding valves allow for commissural alignment techniques.[12] During procedural execution, the key step is visualisation of the sewing ring as a landmark. Contrast angiography will be required if visualisation is poor on plain cineangiography. The TAVI valve siting should be as with normal practice, with sewing ring envisioned as virtual annulus. Deployment should be under rapid ventricular pacing to avoid valve embolisation, with smooth and slow valve deployment and release. Valve stability may be assessed on postdeployment contrast angiography. If significant paravalvular leak is seen, additional valves may be required. Concurrent coronary angiography is useful in the assessment of coronary anatomy and early coronary obstruction, and serves as a reference for future coronary intervention attempts. In conclusion, the challenges faced when performing VIV TAVI in patients with prior bioprosthetic Bentall procedures are contributed by both the rarity of Bentall procedure itself and the uncommon decision of performing TAVI with its associated technical intricacies. Multiple technical factors need to be considered to ensure the safety and good outcome of VIV TAVI in failing valve post-bioprosthetic Bentall procedure. Acknowledgement We would like to express our gratitude to all who were involved in patient care. Financial support and sponsorship Nil. Conflicts of interest There are no conflicts of interest.
No takes yet. Share an insight, caveat, or question.
Chew et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: