This study presents the first ion temperature (\(T_i\)) measurements from the MAST-U divertor using a Retarding Field Energy Analyzer (RFEA). Embedded within the flat tile of the closed divertor chamber, the RFEA captures \(T_i\) profiles across various plasma scenarios, including transitions to the Super-X configuration. Measurements were conducted under steady-state and transient plasma conditions characterized by a plasma current (\(I_p\)) of 750 kA, electron density (\(n_e\)) between \(2.2 × 10¹⁹\) and \(4.45 × 10¹⁹\,m⁻³\), and Neutral Beam Injection (NBI) power ranging from 3.0 MW to 3.2 MW. The ion temperatures, peaking at approximately 20 eV in steady state, were compared with electron temperatures (\(T_e\)) obtained from Langmuir probes (LP) at identical radial positions. The study also examined ion saturation current density (\(Jₛₐₜ\)) signals to using methodologies similar to previous MAST experiments. Preliminary findings reveal a \(T_i/T_e\) ratio ranging from 1 to 2.5. Additionally, high temporal resolution measurements (100 μ s) captured the dynamics of Edge Localized Modes (ELMs), showing \(T_i\) peaks at 16.03 +- 1.84 eV during ELM events, nearly three times higher than inter-ELM temperatures.
No takes yet. Share an insight, caveat, or question.
Damizia et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: