The digital voltage controller of power converters is used because it has many advantages over its analog counterparts. Thus, in this paper, a controller of digital voltage mode is designed and analyzed for a non-isolated DC-DC buck converter in continuous conduction mode (CCM). First, an analog controller is designed using a Bode plot to achieve the desired stability margins in the frequency domain. Next, the analog controller is discretized using bilinear transformation with the pre-warping method. The characteristics of the discretized compensator can be maintained close to the corresponding analog compensator as long as a proper sampling time is selected. The digital control scheme is simulated with a nonlinear DC-DC buck converter model in MATLAB/Simulink to investigate the controller performance. The simulation results demonstrated the validation of the proposed digital voltage-mode control design approach. The developed digital controller eliminates DC error by tracking the reference voltage, achieving a fast transient response, maintaining specified stability margins, and effectively rejecting large disturbances.
No takes yet. Share an insight, caveat, or question.
Abdulsada et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: