This paper presents a study of the performances of a permanent magnet synchronous generator (PMSG) used in small scale wind energy applications. The d-q model is adopted for the performance analysis of the PMSG under variable operating conditions. In addition, in order to validate the results obtained with the theoretical model, an experimental test bench based on a small PMSG equipped with a data acquisition system has been developed. The study carried out on the experimental test bench made it possible to determine both the dynamic and the steady state performances of the PMSG under variable loads and rotational speeds.
No takes yet. Share an insight, caveat, or question.
Benhacine et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: