The disorder and disaster evolution characteristics of ascensional airflow fires in mine ventilation systems has been the focus of mine fire research. In this work, through repeated experiments, the variation characteristics of the temperature and air volume in the main and side branches of an ascensional airflow fire were obtained under different ventilation capacities. Using the TF1M(3D) software to solve the problems of mine physical ventilation and combined with the analysis of an example, the variation in the ascensional airflow fire and the process of disordered airflow in the ventilation system in an entire area mine were described in detail. Fire combustion served as the power source for uncontrolled energy release, and its fire pressure interacted with the thermal resistance of the mine ventilation, directly causing airflow disorder. As the fire intensified, the ascensional airflow fire caused the airflow in the side branch to decrease, stagnate, or reverse. Improving the fan supply capacity can not only help reduce the increase in the ventilation thermal resistance of the side branch but also help avoid the airflow reversal of the side branch. From the regular variation characteristics, the theoretical results were found to be in good agreement with the experimental results.