Due to the seasonality of solar energy, achieving 100 % of annual solar fraction for domestic hot water (DHW) production is only possible by greatly oversizing the collector area of a solar system, thus creating a significant energy surplus in summer. This simulation study investigates the possibility of using this surplus to promote space heating during winter, in a moderate South European climate, to try achieving a total solar fraction of 100 %. Priority is given to the DHW reservoir, diverting the excess heat to an additional large-capacity seasonal thermal energy storage (STES) reservoir. The best configuration for the number of collectors and STES tank volume was assessed through a parametric study, to reach a compromise between a high solar fraction and a reasonable system efficiency. The results showed that a system with 10 m2 of solar collectors and a 30 m3 STES tank or, alternatively, 20 m2 of collectors and a 20 m3 tank achieved the desired solar fraction and efficiency for the chosen building and local climate conditions. A comparison with the literature shows that this strategy can achieve better results, requiring less collector area and storage volume.
No takes yet. Share an insight, caveat, or question.
Brites et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: