As part of the study, a comparative analysis of the results of calculations of the building of a protected control center on the seismic impact of the MSE level was carried out. Two methods were used for the analysis: direct dynamic and linear spectral. The work presented specific calculations for the building of a protected control center. The results showed that the direct dynamic method gives more accurate results, allowing to take into account all the dynamic features of the building and its behavior under seismic conditions. The linear spectral method has also been shown to be effective in providing a quick assessment of the stability of a building based on the spectrum of ground accelerations.
No takes yet. Share an insight, caveat, or question.
A.S. Kornilova (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: