In the present study, the PCM layer is integrated into the roof, analyzed, and compared for its thermal behaviour in terms of Indoor Air Temperature Reduction (IATR), Thermal Load Levelling (TLL), and Lag Time (LT) to determine the ideal position, thickness, and type of PCM. The observations from the experimental analysis were validated using COMSOL Multiphysics v6.0 with available literature. The results showed that PCM-integrated roofs reduced the interior temperature by around 30%. Furthermore, the fluctuations in the interior temperatures were reduced to 6.1% with PCM integration within the roof. A lag time of 5–8.25 h was observed for the PCM roofs. The study also found that the material properties impact the overall thermal behaviour of the PCM-integrated roofs. These properties were further explored using continuous cyclic thermal loading and variation of latent heat over a period of four days for three climatic zones in India.