Abstract 3D metal halide perovskite X‐ray detectors have become the focus of research in recent years due to their superior sensitivity. However, the reported efficient perovskite X‐ray detectors all contain highly toxic lead and worrisome stability, which greatly limits their wide application and promotion. In this study, a distorted 3D germanium perovskite MAGeI 3 single crystal (SC) is designed and grown by gradient cooling method. Due to its distorted octahedral structure, the MAGeI 3 SCs not only possess high sensitivity but also have superior long‐term working stability. Specifically, the MAGeI 3 SC X‐ray detectors achieve a record sensitivity of 42825 µC Gy −1 cm −2 and an impressive low detection limit of 4.1 nGy s −1 , both of them are far better than the state‐of‐the‐art lead‐free perovskite SC X‐ray detectors. Moreover, the unencapsulated SC detector still maintains the original response even at high applied electric field and high dose rate X‐ray irradiation for several hours. Eventually, a high resolution of 7.2 lp mm −1 in X‐ray imaging is demonstrated on the MAGeI 3 SC detector under a low dose rate of 478 nGy s −1 and at a low electric field of 1 V mm −1 . This work provides a new pathway to design high‐performance and low‐toxicity X‐ray detectors.