Answers are grounded in this paper and cite their sources.
The flow-induced rotation of coupled double cylinders in tandem has rarely been investigated in existing studies. In this paper, the theoretical basis of flow-induced rotation was established, the experimental setup was established and verified. Based on the test data, the flow-induced rotation characteristics of coupled double cylinders arranged in tandem were investigated. The study aims to provide reference for the design of the flow-induced vibration energy conversion equipment. The main conclusions can be summarized as follows: The oscillation response of coupled double cylinders arranged in tandem is vortex-induced vibration (VIV). When the spacing ratio of coupled double cylinders is 4.0, the amplitude is low and a “re-growth zone” is observed in the lower branch of VIV. When the spacing ratio is 6.0, the amplitude is high, and the maximum arc length ratio (A*) is 0.92. When the spacing ratio is 8.0, the lock-in range is wide. The effect of system stiffness (K) on flow-induced rotation response is not sensitive. The width of lock-in range is similar under different stiffness, while the desynchronization and the frequency response in the non-locked range are significantly different. The maximum arc length ratio is 0.98, which occurs at K = 1400N/m.
No takes yet. Share an insight, caveat, or question.
Feng et al. (2024) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: