Aquifer thermal energy storage (ATES) has proven to be an effective way to mitigate energy production and supply issues. Drilling branching holes from traditional vertical wells can enhance the injection and production capacity of the ATES system. There are many influencing parameters and evaluation indexes of ATES system with multilateral wells. It is necessary to conduct a comprehensive analysis of the system performance. Therefore, a three-dimensional numerical model of fluid flow and heat transfer for the multilateral-well ATES system is built with COMSOL and verified with experimental data. Then, the multilevel orthogonal tests are carried out to analyze 6 factors with 5 values. The grey correlation method is used to compare the influence of key parameters on energy utilization coefficient and coefficient of performance (COP) of hot well. The results show that there are great differences in the order of parameter correlation degree under different indicators. So this study determines the weights of four evaluation indicators based on the Analytic Hierarchy Process (AHP). The optimal scheme is selected from 25 orthogonal experiments by fuzzy comprehensive evaluation. The optimization method established in this study can comprehensively evaluate the operating performance of multilateral-well ATES system and provide reference for its reasonable design.
No takes yet. Share an insight, caveat, or question.
Li et al. (2024) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: