Conventional 5-level active neutral-point-clamped (5L-ANPC) topology and state-of-the-art 5-level hybrid active neutral-point-clamped (5L-HANPC) topology are popular for inverter applications. However, their dc-link voltage utilization is limited to only 50%. With the maximum voltage level generated by only half dc-link voltage, these inverters are not capable of boosting voltage in their ac output. To resolve these drawbacks, this paper proposes a family of four novel 5-level boost-active neutral-point-clamped (5L-BANPC) inverters. Without requiring any flying capacitors, the proposed topologies can generate five voltage levels by effectively using the dc-link capacitors. The dc-link voltage utilization of the proposed 5L-BANPC inverters is twice that of the 5L-ANPC and 5L-HANPC topologies. While generating the five-level ac output voltage, natural voltage balancing of both dc-link capacitors and voltage boosting are achieved. Ease of implementation is another noteworthy merit of the proposed 5L-BANPC inverters because they can be implemented using six widely available commercial half-bridge modules without requiring a dedicated circuit design. The operation of the proposed topologies is analyzed. Experimental results are presented for verification.
No takes yet. Share an insight, caveat, or question.
Sze Sing Lee (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: