The synchronization of symbols in Optical Camera Communication (OCC) is crucial for systems in both global and rolling shutter operations. Global shutter OCC systems sample the received data using a frame acquisition mechanism that presents particularly high jitter while rolling shutter OCC systems are based on a line acquisition mechanism that is commonly synchronized to a closed hardware clock switching at a fixed period. Thus, all OCC systems require regular clock detection for correct demodulation. In this paper, we test a m-ary Pulse Amplitude Modulation (PAM) with m=8 with a novel line code denominated self-clocking constant-power (SCCP)-PAM. The system was implemented using a global shutter operation, utilizing small scale Light Emitting Diode (LED) and camera, at a distance of 15 ~m with artificial constant ambient light, showing bit-error rate (BER) values under $1 %$ at data rates of 50bps per node, and a high node capacity given the small scale of the optical devices. The BER obtained can be further improved using matched filters given the clock-extraction capability of the system.