Prospective experiment demonstrates that false-positive AI findings increase aneurysm suspicion among radiologists, highlighting susceptibility to automation bias during magnetic resonance...
Background AI systems have the potential to support in detecting cerebral aneurysms. Yet, the role of automation bias (inclination of humans to overly rely on automated decision-making systems) in AI-assisted cerebral aneurysm detection remains unclear. Purpose To determine how automation bias can affect radiologists with varying experience levels when reading time-of-flight magnetic resonance angiography (TOF-MRA) studies with the assistance of an AI system for cerebral aneurysm detection. Methods In this prospective experiment, nine radiologists with varying levels of experience evaluated twenty TOF-MRA exams for the presence of anterior circulation aneurysms, with each arterial segment rated on a 4-point Likert scale, and provided follow-up recommendations. Every case was evaluated twice (with or without assistance by the AI software © mdbrain), with a washout-period of at least four weeks between the two sessions. Ten out of twenty cases included at least one false-positive AI finding. Aneurysm ratings, follow-up recommendations, and reading times were assessed using the Wilcoxon signed-rank test. A thematic analysis was performed to summarize reader feedback and observations. Results False-positive AI results led to significantly higher suspicion of aneurysm findings (p = 0.01). Inexperienced readers further recommended significantly more aggressive follow-up examinations when presented with false-positive AI findings (p = 0.005). Reading times were significantly shorter with AI assistance in inexperienced (164.1 vs 228.2 seconds; p < 0.001), moderately experienced (126.2 vs 156.5 seconds; p < 0.009), and very experienced (117.9 vs 153.5 seconds; p < 0.001) readers alike. Conclusion Our results demonstrate susceptibility of radiology readers to automation bias in detecting cerebral aneurysms in TOF-MRA studies when encountering false-positive AI findings. In inexperienced readers, this behavior further translated into more aggressive follow-up recommendations. AI assistance resulted in significantly shorter reading times across experience levels. While AI systems for cerebral aneurysm detection can provide benefits, challenges in human-AI interaction need to be mitigated to ensure safe and effective adoption.
No takes yet. Share an insight, caveat, or question.
Kim et al. (2024) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: