Air quality measurement is essentially important to create a safe and healthier environment. In this study, the accuracy and precision of the Grove HM-3301 sensor were evaluated and compared with the data taken from a standard air quality monitoring meter. Using the low-cost air particulate measuring sensor, the measuring results of the PM 1 , PM 2.5 , and PM 10 concentration was fairly accurate, with a relative bias smaller than 30 %. The accuracy of the HM-3301 sensor can be improved using single-point calibration, with relative bias reduced to the limit of 13 % as tested in the particle mass concentration limit within 500 μg/m 3 . With improved accuracy, the air particulate IoT system using the HM-3301 sensor can be employed in practical applications to assess air quality. With a development cost of 90 USD, the PM measurement IoT system is suitable to be applied in monitoring outdoor and indoor air quality.
No takes yet. Share an insight, caveat, or question.
Yu et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: