Answers are grounded in this paper and cite their sources.
To measure the high-energy part of the energy distribution function of ions in a hot plasma using the pellet charge exchange (PCX) diagnostic, it is necessary to know the energy dependence of the fraction F 0 ( E ) of fast ions neutralized when intersecting a pellet cloud. Using experimental and calculated data on the ablation of polystyrene macroparticles (pellets) in the LHD stellarator, the function F 0 ( E ) for protons in the hydrocarbon cloud has been calculated in the energy range of 50–1000 keV at pitch angles 1pt 70^∘ . At energies of 50‒200 keV, it is necessary to take into account the decrease in the flux of neutralized protons multiply intersecting the cloud. Energy losses of protons along the trajectory provide a lower bound E > 100 keV for the possible PCX measurements. The necessity of the control of the charge state composition and structure of the cloud limits the view area of the detector of atoms within ±30 mm from the position of a pellet along the magnetic field. For this reason, the injection axis should be aligned with the observation axis of the neutral particle analyzer for the optimal geometry of PCX measurements with polystyrene pellets.
No takes yet. Share an insight, caveat, or question.
Bakhareva et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: