State-of-the-art techniques like dual-frequency Time-Domain Thermoreflectance (TDTR) and Frequency-Domain Thermoreflectance (FDTR) offer superb capability for simultaneous measurements of thermal conductivity and heat capacity with a spatial resolution on the order of 10 {μ}m. However, their applicability is limited to highly conductive materials with an in-plane thermal conductivity exceeding 10 W/(m*K). In this paper, we introduce the Square-Pulsed Source (SPS) technique, offering a novel approach to concurrently measure thermal conductivity and heat capacity with a 10 {μ}m spatial resolution, while significantly extending the measurable thermal conductivity range to an unprecedented low of 0.1 W/(m*K), offering enhanced versatility. To demonstrate and validate its efficacy, we conducted measurements on various standard materials--PMMA, silica, sapphire, silicon, and diamond--spanning a wide thermal conductivity range from 0.1 to 2000 W/(m*K). The obtained results exhibit remarkable agreement with literature values, with a typical measurement uncertainty of less than 10% across the entire thermal conductivity range. By providing a unique capability to characterize both highly and lowly conductive materials with micron-scale spatial resolution, the SPS method opens new avenues for understanding and engineering thermal properties across diverse applications.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: