Abstract Carbon dioxide (CO₂) is commonly used for euthanasia of laboratory animals but has potential negative side effects. There is an urgent need to identify alternatives causing minimal distress while providing a fast and reliable loss of consciousness (LOC). We evaluated different CO₂ concentrations (30% and 70%) and explored carbon monoxide (CO) and nitrogen (N₂) as alternatives for a more humane euthanasia in rats. Isoflurane anesthesia was included as a reference. We assessed relevant physiological parameters in rats using a multifaceted approach combining EEG, ECG, telemetry, EMG, respiration, behavior, biochemical stress parameters, and lung histopathology. 70% CO₂ resulted in rapid LOC and a faster death compared to 30% CO₂ thus minimizing the time of consciousness in which distress and eventually pain can be experienced. Nevertheless, a higher amount of distress (e.g. gasping, arrhythmia or seizures) experienced until LOC might outweigh the benefits of a faster LOC. CO and N₂ resulted in longer times to LOC, induced seizures before LOC, increased stress levels and caused higher lung damage. Therefore, CO and N₂ are no humane alternatives to CO₂ and should not be used for euthanasia of rodents. However, combining CO₂ with anesthetic gases might be suitable to induce a more humane euthanasia.
No takes yet. Share an insight, caveat, or question.
Seebeck et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: