Answers are grounded in this paper and cite their sources.
In this study, we analyzed the relaxation behavior of amorphous structure inside polystyrene injection moldings, and investigated the annealing temperature dependence of increase in heat distortion temperature (HDT) as physical heat resistance using enthalpy relaxation, in order to establish a guideline for annealing conditions. In the thickness direction of polystyrene injection moldings, molecular orientation in the core layer was relaxed by annealing below glass transition temperature (Tg), but the molecular orientation in the skin layer was not relaxed below Tg. Meanwhile, excess enthalpy was relaxed by annealing below Tg in both the skin layer and the core layer. We then investigated the annealing temperature dependence of the enthalpy relaxation and HDT using polystyrenes with different Tg. As a result, we clarified that there was an optimum annealing temperature in terms of both enthalpy relaxation and increase in HDT when the annealing time was 336 hours. Also, in polystyrenes with different Tg, the optimum annealing temperature differed. Focusing on the temperature difference (Tg―Ta) between Tg and annealing temperature (Ta), HDT was maximum at the same Tg―Ta, regardless of the Tg of the polystyrene. We clarified that the optimum annealing temperature is about Tg―25℃ in the case of annealing for 336 hours.
No takes yet. Share an insight, caveat, or question.
Tao et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: