Key result
Dual-energy lattice ablation is non-inferior to conventional RFA for 1-year persistent AF effectiveness.
Why the study?
Is catheter ablation using a dual-energy (pulsed field and radiofrequency) large-tip lattice catheter non-inferior in effectiveness and safety compared to conventional radiofrequency ablation in patients with persistent atrial fibrillation?
RCT (n=420)
Single-blind
randomized, non-inferiority
Is catheter ablation using a dual-energy (pulsed field and radiofrequency) large-tip lattice catheter non-inferior in effectiveness and safety compared to conventional radiofrequency ablation in patients with persistent atrial fibrillation?
Answers are grounded in this paper and cite their sources.
A dual-energy (pulsed field and radiofrequency) lattice-tip catheter demonstrated non-inferior 1-year effectiveness and safety with shorter procedural times compared to conventional radiofrequency ablation in patients with persistent atrial fibrillation.
Clinical outcomes of catheter ablation for atrial fibrillation (AF) are suboptimal due, in part, to challenges in achieving durable lesions. Although focal point-by-point ablation allows for the creation of any required lesion set, this strategy necessitates the generation of contiguous lesions without gaps. A large-tip catheter, capable of creating wide-footprint ablation lesions, may increase ablation effectiveness and efficiency. In a randomized, single-blind, non-inferiority trial, 420 patients with persistent AF underwent ablation using a large-tip catheter with dual pulsed field and radiofrequency energies versus ablation using a conventional radiofrequency ablation system. The primary composite effectiveness endpoint was evaluated through 1 year and included freedom from acute procedural failure and repeat ablation at any time, plus arrhythmia recurrence, drug initiation or escalation or cardioversion after a 3-month blanking period. The primary safety endpoint was freedom from a composite of serious procedure-related or device-related adverse events. The primary effectiveness endpoint was observed for 73.8% and 65.8% of patients in the investigational and control arms, respectively (P < 0.0001 for non-inferiority). Major procedural or device-related complications occurred in three patients in the investigational arm and in two patients in the control arm (P < 0.0001 for non-inferiority). In a secondary analysis, procedural times were shorter in the investigational arm as compared to the control arm (P < 0.0001). These results demonstrate non-inferior safety and effectiveness of the dual-energy catheter for the treatment of persistent AF. Future large-scale studies are needed to gather real-world evidence on the impact of the focal dual-energy lattice catheter on the broader population of patients with AF. ClinicalTrials.gov identifier: NCT05120193 .
No takes yet. Share an insight, caveat, or question.
Anter et al. (2024) conducted an RCT in Persistent atrial fibrillation (n=420). Dual-energy (pulsed field and radiofrequency) large-tip lattice catheter ablation vs. Conventional radiofrequency ablation system was evaluated on Composite effectiveness endpoint through 1 year: freedom from acute procedural failure and repeat ablation at any time, plus arrhythmia recurrence, drug initiation or escalation or cardioversion after a 3-month blanking period (p=< 0.0001 for non-inferiority). Dual-energy lattice-tip catheter ablation was non-inferior to conventional radiofrequency ablation for 1-year composite effectiveness in persistent AF.
Synapse has enriched 10 related papers. Consider them for comparative context: