Maintaining optimal liquid levels in tanks is crucial across various practical applications to avoid complications stemming from over-filling or under-filling. The Proportional Integral Differential (PID) controller stands out as a popular choice for achieving precise control in such scenarios. In the paper, the parameters of the PID controller were determined utilizing the classic Ziegler-Nichols (ZN) method alongside its variations such as the PID Pessen Integral Rule and PID with overshoot, as well as employing the Auto-Tuning method. The validation of the efficacy of these selection methods was conducted by comparing the performance of the transient response and by calculating performance indexes such as Integral Error (IE), Integral of Absolute Error (IAE), Integral of Square Error (ISE), Integral of Time Absolute Error (ITAE), and Integral of Time Square Error (ITASE). Utilizing Simulink, a program package within MATLAB, an approach to calculate these performance indexes is presented. The method is tested across single, double, and triple tank systems, with results showcasing both stationary values and dynamic changes in indexes throughout simulation runs. Obtained findings indicate that the PID controller exhibits effectiveness in liquid-level control applications, as evidenced by the obtained performance indexes as well as parameters of the transient response. Performance Indexes Calculation of PID Controllers for Different Tank Systems.
No takes yet. Share an insight, caveat, or question.
Antić et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: