Experimental testing demonstrates robust open-circuit fault diagnosis in dual pulse rectifiers, suggesting reliable switch localization without extra sensors.
This letter proposes a current similarity-based robust diagnosis scheme to detect open-circuit (OC) faults for insulated gate bipolar transistors (IGBTs) in dual pulse rectifiers. The similarity indicator between the AC-side currents of the two rectifiers is calculated based on the structural characteristics, which are independent of system parameters and naturally robust to voltage fluctuations and load changes. Also, it avoids modeling or additional sensors. Then a proper threshold is designed by analyzing variable behaviors under various normal and faulty operating conditions. Finally, the faulty switches are located by the integrals of the extracted DC-side current and designed timesequence current indicators without injecting specific driving signals. The effectiveness of the proposed fault diagnosis method is demonstrated by both simulation and experimental testing.
No takes yet. Share an insight, caveat, or question.
Deng et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: