Answers are grounded in this paper and cite their sources.
Introduction: The precision of impressions has a significant impact on the marginal adaptation of fixed restorations. Fit is the most significant factor influencing the restoration's durability, retention, and periodontal health. Aim of study: to compare the marginal fit of CAD/CAM zirconia crowns manufactured using two distinct digital impression techniques. Materials and methods: A typodont tooth in the upper premolar region was prepared to receive a complete ceramic crown. A direct scan of the prepared tooth was used to create twenty 3D-printed resin impressions. The master dies were divided into two groups at random (n = 10 per group). Group I: scanning the dies digitally. Group II: digital digitization of the scannable impressions of scannable silicone. Using cone beam CT, the marginal gap and marginal discrepancy were evaluated. Results: Group I had a marginal gap of (119.5 ± 27.0) µm, which was substantially smaller than Group II's (144.8 ± 25.23) µm, and a marginal discrepancy of (107.5 ± 36.36) µm, which was smaller than Group II's (154.3 ± 49.53) µm. Conclusion: Although direct digital scanning was superior to indirect digital scanning in terms of marginal fit, all tested techniques yielded clinically acceptable fit values. Keywords: Marginal fit, CAD/CAM, digital impression. Running title: Marginal fit of zirconia crowns fabricated by direct and indirect digital scanning.
No takes yet. Share an insight, caveat, or question.
Ramadan et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: